NASA’s Langley Research Center has released technical guidance regarding the use of instrumented hammer tests, emphasizing that the validity of these tests is determined by measurement accuracy rather than the shape of the input waveform. The bulletin, authored by Joel W. Sills and colleagues, notes that while hammer tests are frequently used for modal analysis and pyroshock testing, there is a common misconception that an idealized half-sine waveform is required for a successful result.

According to the guidance, variations such as crest ripples or separated contacts do not inherently invalidate a test record. Instead, the adequacy of the data depends on factors including measurement bandwidth, signal-to-noise ratios, and the ability of the excitation to meet specific test objectives. The report highlights that while a finite half-sine pulse is broadband, it contains spectral notches that may not provide sufficient excitation across all necessary frequencies.

Advertisement

The bulletin outlines several recommended practices for engineers conducting these tests. Practitioners are advised to ensure that the complete applied force is measured with proper calibration and time synchronization. Furthermore, response measurements must be monitored to avoid clipping or saturation. The authors stress that tests should only be rejected if a specific deficiency in measurement, excitation, or coverage is identified, rather than based on the visual appearance of the force history.

Source: NASA